UL TYPE MC-HL Cable MC 10AWG 600 Volt Metal Clad Armor Armored Wire Cables for Hazardous Locations Type MC-HL for Classes I, II, and III Division 1 and 2
Metal-clad MC Armored 10AWG 10 AWG Wire Cable for hazardous locations as defined in UL 2225.

MC-HL Armor Armored Cables
UL Type MC-HL MC Metal Clad Cable Wire for Hazardous Locations 10AWG 10 AWG
MC Wire Cable for Hazardous Locations 10AWG Multi Conductor 2 3 4 5 7 9 12 37 Conductors. 600 Volt 600V Hazardous Location MC Metal Clad Wires Cables Wiring Cabling 10AWG
MC-HL MC Metal Clad Hazardous Location Wire Cable Applications:
- Designed for use on power or control circuits
- Can be installed in cable tray, wire ways, racks, or buried directly
- Suitable for exposure to hazardous locations, Type MC-HL for Classes I, II, and III Division 1 and 2

midsouth wire and cable logo
1-800-843-6036

Type MC-HL MC Armored Wire Cable for Hazardous Location Classes I, II, and III Division 1 and 2

MC Wire Cable for Hazardous Locations 10AWG Multi Conductor 2 3 4 5 7 9 12 37 Conductors

iStock_000012125952XSmall

UL Type MC-HL 10AWG 10 AWG MC Armored Wire Cable Standards:
- UL 44, XHHW-2 600 Volt conductors
- UL 1569 Type MC and UL 2225 Type MC-HL
- Designated Type MC as per NEC Article 334
- Passes UL and IEEE 383 vertical tray fire tests at 70,000 BTU/hr, ICEA T-29-520 fire test at 210,000 BTU/hr, IEC 332-3 category A fire test, IEEE 1202, and CSA FT4

600 Volt Armor Armored MC Metal Clad Cables Wires for Hazardous Locations 10AWG 10 AWG

10 AWG MC Wire Cable Metal Clad Armor Armored 10AWG 600V
UL Type MC-HL Wires Cables 10AWG for Hazardous Locations

PART#
AWG
Conductors
Ground Size
Nom. O.D. Inches*
Weight Lbs./M-FT*
MCHL-1002
10
2
10
.658
240
MCHL-1003
10
3
10
.720
312
MCHL-1004
10
4
10
.730
343
MCHL-1005
10
5
10
.855
423
MCHL-1007
10
7
10
.882
509
MCHL-1009
10
9
10
1.02
630
MCHL-1012
10
12
10
1.08
758
MCHL-1037
10
37
10
1.72
2070


















UL MC-HL 10AWG MC Armored Wires Cable Suitable for exposure to hazardous locations, Type MC-HL for Classes I, II, and III Division 1 and 2

WE CAN:
Cut to your length requirements**
Ship to your Job Site
Ship from Warehouses Nation-Wide



pasted-graphic-1

1-800-843-6036

email us for quotes

UL TYPE MC-HL Cable 10AWG 600 Volt Metal Clad Armor Armored Wire Cables for Hazardous Locations Type MC-HL for Classes I, II, and III Division 1 and 2
Metal-clad MC Armored 10AWG 10 AWG Wire Cable for hazardous locations as defined in UL 2225.

MC-HL Armor Armored Cables
UL Type MC-HL MC Metal Clad Cable Wire for Hazardous Locations 10AWG 10 AWG
MC Wire Cable for Hazardous Locations 10AWG Multi Conductor 2 3 4 5 7 9 12 37 Conductors. 600 Volt 600V Hazardous Location MC Metal Clad Wires Cables Wiring Cabling 10AWG
MC-HL MC Metal Clad Hazardous Location Wire Cable Applications:
- Designed for use on power or control circuits
- Can be installed in cable tray, wire ways, racks, or buried directly
- Suitable for exposure to hazardous locations, Type MC-HL for Classes I, II, and III Division 1 and 2

MC-HL / MC Armored Cable for Hazardous Locations
14AWG UL TYPE MC-HL
12AWG UL TYPE MC-HL
10AWG UL TYPE MC-HL

Standards:
Note: The data shown is approximate and subject to standard industry and manufacturer tolerances.
*Values are approximate and are subject to change without notice.
Shipping tolerances +/- 10%
Prices are subject to change without notice.  Inventory is subject to prior sale.  Product design, specifications & construction are subject to change without notice. Pictures are for general representational purposes and may not represent actual product. Not Responsible for errors in print, verify all data with us or manufacturer.  Terms & Conditions of sale apply, for a copy contact us. Listed values are approximate and for general estimation purposes only.
Products may be discontinued without notice. Other disclaimers may apply. **Minimum order quantities apply.**