UL TYPE MC-HL Cable MC 10AWG 600 Volt Metal
Clad Armor Armored Wire Cables for Hazardous
Locations
Type MC-HL for Classes I, II, and III Division 1
and 2
Metal-clad MC Armored 10AWG 10 AWG Wire Cable for
hazardous locations as defined in UL 2225.
MC-HL Armor Armored Cables
UL Type MC-HL MC Metal Clad Cable Wire for
Hazardous Locations 10AWG 10 AWG
MC Wire Cable for Hazardous Locations 10AWG Multi
Conductor 2 3 4 5 7 9 12 37 Conductors. 600 Volt
600V Hazardous Location MC Metal Clad Wires
Cables Wiring Cabling 10AWG
MC-HL MC Metal Clad Hazardous Location Wire Cable
Applications:
- Designed for use on power or control circuits
- Can be installed in cable tray, wire ways,
racks, or buried directly
- Suitable for exposure to hazardous locations,
Type MC-HL for Classes I, II, and III Division 1
and 2
1-800-843-6036
Type MC-HL MC Armored Wire Cable for Hazardous
Location Classes I, II, and III Division 1 and 2
MC Wire Cable for Hazardous Locations 10AWG Multi
Conductor 2 3 4 5 7 9 12 37 Conductors
UL Type MC-HL 10AWG 10 AWG MC Armored Wire Cable
Standards:
- UL 44, XHHW-2 600 Volt conductors
- UL 1569 Type MC and UL 2225 Type MC-HL
- Designated Type MC as per NEC Article 334
- Passes UL and IEEE 383 vertical tray fire tests
at 70,000 BTU/hr, ICEA T-29-520 fire test at
210,000 BTU/hr, IEC 332-3 category A fire test,
IEEE 1202, and CSA FT4
600 Volt Armor Armored MC Metal Clad Cables Wires for Hazardous Locations 10AWG 10 AWG
10 AWG MC Wire Cable Metal Clad Armor Armored
10AWG 600V
UL Type MC-HL Wires Cables 10AWG for Hazardous
Locations
PART#
|
AWG
|
Conductors
|
Ground Size
|
Nom. O.D. Inches*
|
Weight Lbs./M-FT*
|
MCHL-1002
|
10
|
2
|
10
|
.658
|
240
|
MCHL-1003
|
10
|
3
|
10
|
.720
|
312
|
MCHL-1004
|
10
|
4
|
10
|
.730
|
343
|
MCHL-1005
|
10
|
5
|
10
|
.855
|
423
|
MCHL-1007
|
10
|
7
|
10
|
.882
|
509
|
MCHL-1009
|
10
|
9
|
10
|
1.02
|
630
|
MCHL-1012
|
10
|
12
|
10
|
1.08
|
758
|
MCHL-1037
|
10
|
37
|
10
|
1.72
|
2070
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
UL MC-HL 10AWG MC Armored Wires Cable Suitable
for exposure to hazardous locations, Type MC-HL
for Classes I, II, and III Division 1 and 2
WE
CAN:
Cut
to your length requirements**
Ship to your Job Site
Ship from Warehouses Nation-Wide
1-800-843-6036
email
us for quotes
UL TYPE MC-HL Cable 10AWG 600 Volt Metal Clad
Armor Armored Wire Cables for Hazardous
Locations
Type MC-HL for Classes I, II, and III Division 1
and 2
Metal-clad MC Armored 10AWG 10 AWG Wire Cable for
hazardous locations as defined in UL 2225.
MC-HL Armor Armored Cables
UL Type MC-HL MC Metal Clad Cable Wire for
Hazardous Locations 10AWG 10 AWG
MC Wire Cable for Hazardous Locations 10AWG Multi
Conductor 2 3 4 5 7 9 12 37 Conductors. 600 Volt
600V Hazardous Location MC Metal Clad Wires
Cables Wiring Cabling 10AWG
MC-HL MC Metal Clad Hazardous Location Wire Cable
Applications:
- Designed for use on power or control circuits
- Can be installed in cable tray, wire ways,
racks, or buried directly
- Suitable for exposure to hazardous locations,
Type MC-HL for Classes I, II, and III Division 1
and 2
MC-HL / MC Armored Cable for Hazardous
Locations
14AWG UL TYPE
MC-HL
12AWG UL TYPE
MC-HL
10AWG UL TYPE
MC-HL
Note: The data shown is approximate and subject to standard industry and manufacturer tolerances.
*Values are approximate and are subject to change without notice.
Shipping tolerances +/- 10%
Prices are subject to change without notice. Inventory is subject to prior sale. Product design, specifications & construction are subject to change without notice. Pictures are for general representational purposes and may not represent actual product. Not Responsible for errors in print, verify all data with us or manufacturer. Terms & Conditions of sale apply, for a copy contact us. Listed values are approximate and for general estimation purposes only.
Products may be discontinued without notice. Other disclaimers may apply. **Minimum order quantities apply.**